  • True Double Beam with highly stable optics
  • 1.5nm spectral bandwidth
  • Includes Jenway Flight Deck Software
  • A range of easy to fit accessories

The Jenway Model 6800 is built on a solid foundation of high quality, sealed optics for optimum photometric performance.
The user-friendly Flight Deck software delivers the intuitive operation you have come to expect from Jenway instruments; while the operator-focus ensures this spectrophotometer will meet the demands of your laboratory, today and into the future.

Operating modes include:

Photometrics/Multi-Wavelength Measure the absorbance or transmittance at one to six wavelengths. The dedicated 'Ratio Mode' allows calculation of the ratio and difference of two or three selected wavelengths. An alphanumeric identity can be entered for each sample. All results are displayed in a simple tabular format for quick and easy export to Excel®, other spreadsheets or databases.

Spectrum Scanning Scan in the range 190 to 1100nm with resolutions of up to 0.1nm and scan speeds up to 3600nm/sec. All data is displayed in both graphical and tabular formats with automatic peak and valley identification as well as manual selection. Post scan manipulations allow multiple overlays, spectrum calculations and derivative spectra to be displayed.

Time Scan and Kinetics Measure the changes in absorbance or transmittance over 30 to 99999 seconds. The concentration or activity values can then be calculated from the display by the free selection of a start and end time for which a regression curve is displayed and calculations made against an adjustable K factor.

Quantitation Enables the accurate measurement of sample concentrations against calibration curves (K factor, 1st to 3rd order) based on up to twenty standards and up to three wavelengths for multi-component analysis. The easy recall of saved calibration curves leads to quicker, more accurate analysis.

DNA/RNA Offers standard methods for measuring DNA, RNA or oligonucleotide concentrations using the absorbance values recorded at 260 and 280nm. The micro cell holder accessory (680 031) allows the accurate measurement of sample volumes down to 50µL.

Protein Offers pre-set methods for measuring protein concentration using the Bradford, Lowry, BCA and Direct UV protocols. Any of the default settings can be modified allowing specific user variations to any of these standard test protocols.

Exporting to Excel By simply clicking the dedicated 'Export to Excel' icon the Jenway 6800 Flight Deck software automatically exports raw data and results to Excel® for further processing or saving.

Accessories To enhance productivity a full range of accessories is available including a micro-cell holder, water heated cell holder, film and glass filter holders and a long path cell holder.