Labnet Biopette Multichannel pipette
Code  NL0100-0010
Classification  液體操作設備及細胞培養液體操作
Size 
Order 加入購物車
Print 
PRODUCT DETAIL
BioPetteTM Multichannel Digital Pipettes
Now fully autoclavable and with volume adjustment from the plunger button
  • Multiple piston assembly for superior accuracy and reproducibility
  • Streamlined handle provides exceptional user comfort
  • Tip ejection system requires minimal force
  • Ideal for high throughput and microplate applications
  • Light weight and well balanced with a new manifold design
  • 8 and 12 channel models
  • Four overlapping volume ranges
  • Fully Autoclavable
Product Information

Ideal for all standard 96 well formats, the Biopette Multichannel Pipettes stand up to the wear and tear of constant use while maintaining excellent accuracy and reproducibility. Four overlapping volume ranges are available to precisely meet liquid handling requirements from 1 µl to 300 µl.


The pipettes fit comfortably in either the right or left hand, with the large digital display visible at all times. The volume adjustment wheel is slightly recessed to prevent accidental change. Volume setting can also be accomplished by turning the push-button. The plunger is positioned to reduce fatigue during extended use while the manifold rotates 360º for comfortable pipetting in any direction. Located near the plunger and accessed easily by the thumb, the tip ejector may be deactivated. The curved ejector design pushes the tips off in steps, thus requiring minimal force to operate.
 
Each channel has an individual, precision piston assembly to ensure accuracy and reproducibility from one pipetting series to the next as well as between channels. The insulated body protects the micrometer from the effects of hand warming, thus maintaining the pipette’s precision, even after prolonged use.

The 1-10 µl pipette is available as an 8 channel model. The other ranges are available as both 8 and 12 channel models. Each pipette is individually tested and supplied with a certificate of quality. A calibration key is also included for in-lab recalibration The Biopettes are fully autoclavable.

Ordering Information
Catalog Number Item Description
P4608-10A Channels 8, Vol Range 1 - 10µl, Accuracy ±8.0 to ±2.0%, Coef. Variation <8.0 to <2.0%, Tip P3984
P4608-50A Channels 8, Vol Range 5 - 50µl, Accuracy ±3.0 to ±1.0%, Coef. Variation <1.8 to <0.5%, Tip P3991/P3992
P4608-200A Channels 8, Vol Range 20 - 200µl, Accuracy ±1.4 to ±0.8%, Coef. Variation <0.7 to <0.5%, Tip P3991/P3992
P4608-300A Channels 8 Vol Range 50 - 300µl, Accuracy ±1.4 to ±0.9%, Coef. Variation <0.7 to <0.5%, Tip P4015/P4016
P4612-50A Channels 12, Vol Range 5 - 50µl, Accuracy ±3.0 to ±1.2%, Coef. Variation <2.0 to <0.5%, Tip P3991/P3992
P4612-200A Channels 12, Vol Range 20 - 200µl, Accuracy ±1.4 to ±0.8%, Coef. Variation <0.8 to <0.5%, Tip P3991/P3992
P4612-300A Channels 12, Vol Range 50 - 300µl, Accuracy ±1.4 to ±0.9%, Coef. Variation <0.8 to <0.5%, Tip P4015/P4016
P5421 Stand for one 8 channel BioPette multichannel pipette
P5422 Stand for one 12 channel BioPette multichannel pipette
P3984 Pipette tips, natural, 10µl max., 96 tips per rack, 10 racks per pack
P3991 Pipette tips, yellow, 200µl max., 96 tips per rack, 10 racks per pack
P3992 As above, in individually wrapped sterile packages
P4015 Pipette tips, natural, 300µl max., 96 tips per rack, 10 racks per pack
P4016 As above, in individually wrapped sterile packages